AZ41E12DAC
GE Zoneline® Deluxe Series Cooling and Electric Heat Unit
Wall Case Dimensions
Dimensions and Installation Information (in inches)
Electrical Wiring
Maximum Cord Extension (in inches)
All wiring, including installation of receptacle, must
be made in accordance with local electrical codes
and regulations.
A
Note: Aluminum wiring may pose special problems –
consult a qualified electrician.
C
Grille Options
Stamped Aluminum Grille – RAG60
Exterior Architectural Louvers Durable Polycarbonate:
21
58
B
RAG61 (Beige)
RAG62 (Maple)
RAG63 (Bittersweet)
RAG67 (Extruded Aluminum)
RAB71 Wall Sleeve
Wall Opening Dimensions
Retrofit Kits:
Heavy-gauge galvanized steel, with insulation.
A – 42", B – 13-3/4", C – 16"
Add 1/4" to A and C dimensions for all cut-out size.
RAB71 16-1/4" Min. H x 42-1/4" Min. W
RAK901L – Wall Case Insulation for use with heat pumps.
RAK40 – Deflector Kit to adapt chassis for use with
existing exterior architectural louvered grilles.
RAB71 available in 16", 24", 28" and 31" depths
RAB77 16-1/2" Min. H x 42-3/8" Min. W
RAB77 Wall Sleeve
Molded SMC fiberglass-reinforced polyester
compound.
A – 42-1/8", B– 13-7/8", C – 16-1/4
Ducted Applications
4100 and 6100 series can be used with ductwork to heat or cool more than one room. RAK6052
Duct Adaptor is applied to top of case over air discharge/RAK601 Duct Extension is applied
to right or left of adaptor. Locally fabricated ductwork may be added to extend to maximum
recommended distance of 15 feet.
230/208 Volt Line Cord Connected Units
Min. Circuit
Protection
(Amps)
Line Cord Electric Heat
Electric
Heater Watts Heat Amps
Electric
Kit
(Btuh)
Electrical Connection
RAK3153A
RAK3203A
RAK3303A
8,600/7,100
11,700/9,600
2,550/2,090
3,450/2,820
11.6/10.6
15.5/14.1
22.3/20.3
15
20
30
230/208 volt units may be plugged into a receptacle. 265 volt units are provided with a junction box
and require direct connection. (NEC Requires 265V Direct Connection) See Architects and Engineers
Design Data Manual for electrical connection information including use of sub-base for direct
connected units. Installation must comply with local electrical codes and regulations.
17,000/13,900 5,000/4,090
230/208 Volt Sub-Base Connected Units
Power Connection kits required on all Zoneline chassis.
Min. Circuit
Protection
Heater Watts Heat Amps (Amps)
Electric Heat
(Btuh)
Electric
Electric
Sub-Base
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
RAK204D15P 8,600/7,100
RAK204D20P 11,700/9,600
2,550/2,090
3,450/2,820
11.6/10.6
15.5/14.1
22.3/20.3
15
20
30
RAK204D30P 17,000/13,900 5,000/4,090
Specification Created 11/09
390586
|
Cooper Lighting Indoor Furnishings Compass 12 User Manual
Crown Stereo Amplifier LPS 1500 User Manual
Curtis MP3 Player MPK7836UK User Manual
Directed Electronics Air Conditioner 530T User Manual
EverFocus Home Security System Ed100 User Manual
Extron electronic Stereo Receiver RGB 201 Rxi User Manual
Garland Convection Oven 680 User Manual
GBC Paper Shredder 3220S User Manual
Gefen Switch GEF DVIKVM 848DL User Manual
Generac Power Systems Switch 004635 2 User Manual